Liquiport 2000 Portable Composite Water Sampler
Home » Liquiport 2000 Portable Composite Water Sampler
Liquiport 2000 Automatic Water Sampler, Composite Configuration
Envco Standard Model Composite Sampler comes with An Interactive menu LED using 4 push buttons on the unit, three roller peristaltic pump capable of lifts to 7 meters, Medium Detection System, PC Software for easy programming, Datalogging function for parameter input including sondes, Three step sampling, rinse, sample, and purge cycle, Flow Proportional Sampling, Time Proportional Sampling, Quantity Proportional Sampling, 94 hour battery* Suction line, and Strainer
Product Description
This sampler is specifically configured to Envco Standards for a composite sampler.
Liquiport 2000 RPT20 Control Unit: 1x user mode (up to 8 available), Power Supply: Battery 12V 12Ah + charger 230VAC IP65, Suitable for buffer operation, Operation Language: English, Sample Distribution: 1 x 20 liter composite container Plastic (glass optional), Electrical Version: Basic version + RS232 cable + ReadWin 2000, Peristaltic Pump: Suction height 7m
Liquiport benefits
Simple and user-friendly menu-guided operation with "Quick-Setup" for rapid commissioning. This unit has one User Mode Standard, up to 8 are optional. A User mode is a preprogrammed location or configuration.
Four main programs are available.
A program can be triggered due to the following criteria:
Time The sample is taken after a preset time.
Quantity The sample is taken after a predetermined measured flow quantity.
Ext. signal The sample is taken when an external signal is active on a digital input.
Flow The sample is taken after a preset time. The sample taken is always proportional to the measured flow rate.
Several criteria can be defined at a time. There is an OR connection among the defined criteria. In other words, once a switching criterion is met, the assigned switching program is executed.
Sampler compartment can be sealed locked and carried separately for easy and safe sample transportation.
Communicative Data Management and RS232 interface for configuring and for data transmission.
Internal Data Logger
The Liquiport 2000 sampler has an internal data logger in which the following measured values can be stored:
Analogue signal (example: flow signal)
Sampling protocol (sample volume, bottle filling times, results).
As an option, the Liquiport has an additional RS232 connection socket for a multi-parameter probe.
The following multiparameter probes can be connected to this connection socket, MultiSens C600, YSI 600R, YSI 600 XL, YSI 600 XLM, YSI 6920, YSI 6820, YSI 6600. The minimum scan rate of the internal data logger is 1 second for the analogue signal and 1 minute for the multi-parameter probe measurements. The contents of the internal data logger can be read out to a PC using
Liquid Handling and Medium Detection System
The medium detection system controls the electronic volume calculation. The medium detection system has a maintenance free ceramic membrane pressure sensor at the heart of the system. The pressure sensor detects the difference between a full and empty pump tube.
The advantages - Intelligent: the suction height is automatically detected and does not have to be configured. Sampling takes place in three steps. Rinsing the suction line: the sampling liquid is sucked in until the medium detection system is triggered. Then the pump runs backwards and pushes the liquid back to the sampling point. The rinsing process can be repeated up to three times. Sucking the sampling liquid: the sampling liquid is sucked from the sampling point to the sampler and the sample volume is calculated electronically. Emptying the suction line: after sampling, the liquid left over in the suction line is pumped back to the sampling point.
You can easily calibrate the sample volume and a three lobe peristaltic pump offers the maximum lift possible.
Specifications
Datalogger Technical
Input
2 x digital signal
1 x analogue signal 0/4-20 mA
Output
2 x digital signal
Enclosure and Housing
Ingress protection Sampler: IP65
Ambient temperature 0C to +40C
Storage temperature -20C to +60C
Operating pressure range Pressureless
Materials
Housing: Polyethylene
Housing components: Polyethylene
Bottles: Polyethylene (Glass Optional)
Sensor housing: Polypropylene
Pump hose: Silicone
Power
Power supply Internal 12 VDC, 12 Ah Lead gel battery
Power consumption max. 29 W
Field-suitable IP65 230 VAC; charge current 3.0 suitable for buffer charging operation
Pump and Sample Storage
Sample storage max. 1 x 20ltr plastic bottle (Glass Option). Other Configurations Available.
Dosing volume 20 to 9999 ml can be set up at the controller
Dosing accuracy +/-5 % of the preset volume
Feed speed > 0.5 m/s, to EN25667
Suction height 8 m
Suction distance 30 m
Dimensions and weight
15 kg (empty weight)
19 kg (incl. battery)
10 kg (upper compartment with battery)
CE mark. The unit fulfils the legal requirements laid down in the EC directives.
Application
Municipal and industrial sewage treatment plants:
Self-monitoring
Process monitoring
Monitoring of indirect dischargers
Manhole monitoring
Authorities and Water Conservancy Boards:
Water protection and water quality
Monitoring of indirect/direct dischargers
Labs and hydrological institutes
Sampling of liquid media


zoom in