zoom in

Liquiport 2000 Automatic Water Sampler Multibottle Configuration

Home » Liquiport 2000 Automatic Water Sampler Multibottle Configuration

Liquiport 2000 Automatic Water Sampler, Multibottle Configuration

Envco Standard Model Composite Sampler comes with an interactive menu display using 4 push buttons as well as power on/off push buttons on the controller, three roller peristaltic pump capable of sample lifts up to 8 metres and a patented medium detection system, Sample Distribution: 24 x 1 liter bottle PE, PC Software for easy programming, Data logging function for analogue measurement input including multi-parameter sensors, Three step sampling, rinse, sample, and purge cycle, Flow proportional sampling, time proportional sampling, quantity proportional sampling, 94 hour battery*, suction line, and filter

Product Description

Envco Standard Model is a Field Ready Sampler when quoted.

This sampler is specifically configured to Envco Standards as a composite sampler.

Liquiport 2000 RPT20
Control Unit: 1x user mode program (up to 7 available)
power supply: 12V 12Ah lead gel battery + 230VAC IP65 battery charger, (suitable for buffer charging)
Operation Language: English, Sample Distribution: 24 x 1 liter bottle, Plastic (24x0.7l glass optional)
Electrical Version: Basic version + RS232 cable + ReadWin 2000
Peristaltic Pump: Suction height 6m standard, optional 8m

Liquiport benefits

Simple and user-friendly interactive menu with "Quick-Setup" for rapid commissioning. This unit has one user mode program as standard, up to 7 programs are possible as an option. A user mode program is a preset location or configuration.


Up to four main programs are available.

A program can be triggered by any of the following criteria:

Time: The sample is taken after a preset time.

Quantity: The sample is taken after a predetermined measured flow quantity.

Ext. signal: The sample is taken when an external signal is active on a digital input.

Flow: The sample is taken after a preset time. The sample volume is always taken proportional to the measured flow rate.

Several sample mode criteria can be defined at a time. There is an OR connection among the defined criteria. In other words, once a switch criterion is met, the assigned switching program is executed.


Sampler compartment can be sealed, locked and carried separately for easy and safe sample transportation.

Communicative Data Management and RS232 interface for configuring and for data transmission.

Internal Data Logger

The Liquiport 2000 sampler has an internal data logger in which the following measured values can be stored:

Analogue signal (example: flow signal)

Sampling protocol (sample volume, bottle filling times, results).

As an option, the Liquiport has an additional RS232 connection socket for a multi-parameter sensor.

The following multi-parameter sensors can be connected to this socket, MultiSens C600, YSI 600R, YSI 600 XL, YSI 600 XLM, YSI 6920, YSI 6820, YSI 6600.

The minimum scan rate of the internal data logger is 1 second for the analogue signal and 1 minute for the multi-parameter sensor measurements. The contents of the internal data logger can be read out to a PC using

Liquid Handling and Medium Detection System

The medium detection system controls the electronic volume calculation. The medium detection system has a maintenance free ceramic membrane pressure sensor at the heart of the system. The pressure sensor detects the difference between a full and empty pump tube.

The advantages - Intelligent: the suction height is automatically detected and does not have to be configured. Sampling takes place in three steps. Rinsing the suction line: The liquid to be sampled is sucked up until the medium detection system is triggered. Then the pump reverses and pushes the liquid back to the sampling point. The rinsing process can be repeated up to three times. Sucking the sampling liquid: the sampling liquid is sucked from the sampling point to the sampler and the sample volume is calculated electronically. Emptying the suction line: after sampling, the liquid left over in the suction line is pumped back to the sampling point.

You can easily calibrate the sample volume and a three roller peristaltic pump offers the maximum lift possible.

Sample distribution

The sample liquid is emptied into single bottles using a revolving distribution tap. Changing distribution systems can be easily done without tools. The Liquiport 2000 also enables a flexible configuration for the sample distribution. Single bottles and bottle groups can be defined for main, switching and event programs.

Time: The distribution tap moves to the next empty bottle after a preset time.

Samples: The distribution tap moves to the next empty bottle after a preset number of samples.

External signal: The distribution tap moves to the next empty bottle when an external signal is active.

Sample storage

The sample bottles are placed in the lower part of the sampler. The samples can be kept cool using crushed ice. The lower part of the sampler can be locked off using an extra lid and can then be transported separately from the upper part.

Specifications

Data logger technical

Input

2 x digital signals

1 x analogue signal 0/4-20mA

Output

2 x digital signal

Enclosure and Housing

Ingress protection sampler: IP65

Medium temperature range 0C to +50C

Ambient temperature 0C to +40C

Storage temperature -20C to +60C

Operating pressure range pressureless

Materials

Housing: Polyethylene

Housing components: Polyethylene

Bottles: Polyethylene (Glass Optional)

Sensor housing: Polypropylene

Pump hose: Silicone

Power

Power supply internal 12 VDC, 12 Ah lead gel battery

Power consumption max. 29 W

Field-suitable IP65 230 VAC; charge current 3A suitable for buffer charging operation

Pump and Sample Storage

Sample storage max. 24 x 1ltr plastic bottle (glass option). Other configurations available.

Dosing volume 20 to 9999 ml can be set up at the controller

Dosing accuracy +/- 5ml or +/- 5 % of the preset volume

Feed speed > 0.5 m/s, to EN25667

Suction height 6 or 8 m

Suction distance 30 m

Dimensions and weight

15 kg (empty weight)

19 kg (incl. battery)

10 kg (upper compartment with battery)


CE mark. The unit fulfils the legal requirements laid down in the EC directives.


Application

Municipal and industrial sewage treatment plants:

Self-monitoring

Process monitoring

Monitoring of indirect dischargers

Manhole monitoring