CT2X Cabled Pressure Conductivity Temperature Logger
Home » CT2X Cabled Pressure Conductivity Temperature Logger
CT2X Cabled Pressure Conductivity Temperature Logger
The AquiStar CT2X is a submersible conductivity/temperature sensor with built-in datalogging. This device stores over 100,000 records of conductivity, temperature, and time data, operates with low power, and features easy to use software with powerful features. The CT2X is also available with a pressure/temperature module, giving added functionality in the same sensor housing.
Product Description
The CT2X incorporates 4-pole electrode cell measurement technology. This technology reduces fringe field interference errors, lessens inaccuracy caused by polarization effects, and lowers contact resistance problems. Four-pole electrode technology also allows users to work with one electrode over a wide range of conductivity.
The conductivity probe is constructed of epoxy/graphite, making it extremely durable for use in rugged field conditions. To clean, simply scrub with a small brush.
FEATURES
RS485/RS232 interface
Small diameter (0.75")
Conductivity, temperature & time with pressure/temperature option
10 microSiemens/cm to 100,000 microSiemens/cm
Linear and nLFn temperature compensation
Also measures TDS in mg/L
100,000+ records / non-volatile
316 stainless steel, Viton and Teflon construction
Polyethylene, polyurethane and FEP Teflon cable options
MODBUS protocol for RTU & PLC applications
Easy export to spreadsheets & databases
OPERATION
The CT2X is powered internally with one 3-volt lithium battery or with an external auxiliary power supply for data intensive applications. Envco offers alkaline, rechargeable, and other auxiliary power systems.
The CT2X comes with powerful, easy-to-use, Windows based Aqua4Plus software, affording the user extensive control, including real time monitoring, flexible programming, easy field calibration, and both tabular and graphic data displays.
Aqua4Plus offers easy, one-point calibration. Simply put the probe in the desired standard, and then use the built-in field calibration utility to adjust to the correct conductivity output.
Linear and non-linear temperature compensation features add flexibility to this sensor. The user can enter specific linear temperature coefficients to match the material being sampled.
Alternately, for natural waters, which do not have linear temperature coefficients, the CT2X has a non-linear natural water mode meeting DIN EN 27888 standards.
Conductivity/Temperature Module
BODY Body Material 316 stainless steel
Probe Material Epoxy/Graphite Electrode 4-pole
Wire Seal Materials Viton and Teflon
Terminating Connector Available
Weight Less than 1 lb.
CABLE
OD 0.28" maximum
Break Strength 138 lbs.
Maximum Length 2000 feet
Weight 4 lbs. per 100 feet
CONDUCTIVITY
Static Accuracy +/-0.5% of measured value
Resolution 0.1 for microSiemens 0.001 for milliSiemens
TDS 0 - 2000 mg/L
Cell Constant .55 (standard)
TEMPERATURE
Accuracy +/-0.2c (at 25c)
Resolution 0.1c
TIME
Accuracy +/-6 sec/day (maximum) +/-2 sec/day (typical)
Operating Temp. Range 0c to 80c
Pressure/Temperature Module (Optional)
BODY
Body Material 316 stainless steel
Wire Seal Materials Viton and Teflon
Terminating Connector Available
Weight Less than 1 lb.
CABLE
OD 0.28" maximum
Break Strength 138 lbs.
Maximum Length 2000 feet
Weight 4 lbs. per 100 feet
PRESSURE
Static Accuracy +/-0.1% FSO (maximum) (B.F.S.L. 25c)* +/-0.06% FSO (typical)
Temperature Error +/-0.5% FSO (maximum)(reference 25c) +/-0.25% FSO (typical)
Maximum +/-0.25% FSO Zero Offset at 25c
Resolution 16 bit
Ranges various from 5-300 psi absolute and gauge
Over Range Protection 2x (except 300 PSIA)
TEMPERATURE
Accuracy +/-0.75c (maximum)
Resolution 0.1c
TIME
Accuracy +/-4 min/yr (maximum) +/-2 min/yr (typical)
Operating Temp. Range 0c to 40c


zoom in